    Eltek Rectiverter 230V 1500VA 110V 1200W 241123.130

    Ask Lasest Price
    Brand Name : Eltek
    Model Number : 241123.130
    Certification : CE
    Price : 320USD
    Payment Terms : T/T
    Supply Ability : 200pcs/month
    Delivery Time : 1 week
    • Product Details
    • Company Profile

    Eltek Rectiverter 230V 1500VA 110V 1200W 241123.130

    Eltek Rectiverter 230V1500VA 110V1200W 241123.130


    Rectifier & Inverter in one box


    • Built on HE technology from the Flatpack2 HE rectifier family the Rectiverter 230/1500 110/1200 provides backed up power for 230 VAC loads with minimum losses and footprint
    • It is a 3 port device capable of charging the 110V battery and simultaneously provides power for the AC and DC loads. During mains outage the Rectiverter feeds AC loads using energy stored in the battery.

    Rectiverter 230V1500VA 110V1200W 241123.130
    Models / ordering information230/1500
    110/1200
    230/1500
    110/1200
    230/1500
    110/0
    115/750
    110/600
    115/750
    110/0
    115/750
    110/0
    Part number241123.130241123.131241123.132241123.130L241123.131L241123.132L
    AC OUTPUT DATA
    Voltage (default) / (adjustable range)230 VAC / 200 - 241 VAC115 VAC / 100 - 128 VAC
    Frequency (default inverter mode)50Hz, 60Hz or last synced 50/60Hz (adaptive), 94-106Hz6)
    Power maximum (continuous / overload (<15s) )1200 W (1500 VA) / 2000 VA600 W (750 VA) / 1000 VA
    Load sharing±5% of active power from 10 to 100% load
    Current maximum (continuous / overload (<15s) )6.5 ARMS / 8.7 ARMS
    Current (maximum) Quick trip (20ms)32 A (6 x nominal)
    THD< 1.5 % at resistive load
    ProtectionFuse in L, Hot pluggable, Varistor
    DC OUTPUT DATA
    Voltage (default) / (adjustable range)122.5 VDC / 97 - 145 VDC
    Power (maximum @nominal input)1200 W 1)150 W0 W 2)600 W 1)75 W0 W 2)
    Current (maximum @VOUT ≤ 108 VDC)11.11 A 1)1.38 A-5.55 A 1)0.69 A-
    Hold up time, maximum output power>10ms; VOUT > 95 VDC (only in rectifier mode)
    Current sharing (10 - 100% load)±5% of maximum current from 10 to 100% load
    Static Voltage regulation (10 - 100% load)±0.5%
    Dynamic Voltage regulation±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms
    Ripple< 500 mVPP , 30 MHz bandwidth
    ProtectionShort circuit proof, Over voltage shutdown, Reversed polarity, ORing FET and Fuse
    INPUT DATA
    AC Mains Input Voltage (range / LV disconnect)185 - 275 VAC / 170 VAC95 - 140 VAC / 85 VAC
    AC Current (maximum)11.5 ARMS9.1 ARMS 3)8.2 ARMS 3)11.3 ARMS10.1 ARMS 3)9.2 ARMS 3)
    Frequency (default: sync range)47-53 & 57-63 Hz47-53 & 57-63 Hz
    Frequency (set-able: sync range)47-53 Hz, 57-63 Hz or both (adaptive)
    Power Factor / THD> 0.99 at 70% load or more / < 3.5%
    AC Input ProtectionFuse in L and N, Hot pluggable, Varistor
    DC Voltage nominal / extended range4)102 - 145 VDC / 90 - 102 VDC
    DC Current (maximum)12.5 A / 18 A during overload (15s)6.3 A / 9 A during overload (15s)
    OTHER SPECIFICATION
    Efficiency>96% (mains mode), >95% (inverter mode)>93% (mains mode), >92% (inverter mode)
    Isolation3.85 kVDC - ACIN/OUT to PE, 3.55 kVDC - ACIN/OUT to DC, 4.25 kVDC - ACIN/OUT to CAN/SYNC, 1.75 kVDC -DC to PE, 3.5 kVDC - DC to CAN/SYNC
    Alarms: Red LED
    Alarm relay [NO max 75 VDC / 100 mA]
    Low and high mains input voltage shutdown, High and low temperature shutdown, Rectiverter Failure,
    Overvoltage shutdown on output, Fan failure, Low output voltage alarm, CAN bus failure, Sync bus
    lost and Sync fail
    Warnings: Yellow LEDRectiverter in power de-rate mode or in power or current limit mode on DC or AC port, Remote output
    current limit activated, Loss of CAN communication with controller
    Normal operation: Green LEDAC output and/or DC output on and ok
    MTBF (Telcordia SR-332 Iss.I method III (a))260 000 hours (@ Tambient : 25 °C)
    Operating temperature-40 to +75°C (-40 to +167°F), humidity 5 - 95% RH non-condensing
    Temperature de-rating above 55°C (131°F)1200W to 480W @ 75°C (167°F) for each, AC and DC, outputs (total power 2000W to 800W)
    Storage temperature-40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
    Dimensions[WxHxD] / Weight109 x 41.5 x 327mm (4.25 x 1.69 x 13”) / 1.95 kg (4.3 lbs)
    DESIGN STANDARDS
    Electrical safetyEN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC/EN 62040-1:2008+A1:2013
    UL 60950-1:2014, UL1778:2014, CSA C22.2 No. 107.3-14
    EMCEN 61000-6-1:2019, -6-2:2019, - 6-3:2007 + A1:2011, - 6-4:2019, IEC 61000-6-5:2015
    EN 62040-2:2006 (C1 emissions, C2/C3 immunity), FCC CFR 47 Part 15
    EN50121 -2:2017+A1:2019, -4:2016+A1:2019, -5:2017+A1:20195)
    EnvironmentEU 2015/863 (RoHS) & 2012/19/EU (WEEE) / ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3)
    Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per
    IEC 62040-5-3:2016 clause 4.3, must be advised

    Eltek Rectiverter 230V 1500VA 110V 1200W 241123.130

    Quality Eltek Rectiverter 230V 1500VA 110V 1200W 241123.130 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing Guoguang Xingda Technology Co.,ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)