    Brand Name : Eltek
    Model Number : 241119.825
    Certification : CE
    Price : 370USD
    Payment Terms : T/T
    Supply Ability : 200pcs/month
    Delivery Time : 1 week
    • Product Details
    • Company Profile

    Eltek Flatpack2 380V Rectifier Module 3000W HE UI 241119.825

    Eltek Flatpack2 380V Rectifier Module 3000W HE UI 241119.825

    • HE rectifier for 380VDC in data centers
    • The Flatpack2 380/3000 HE UI rectifier has high efficiency, ORing protection on output and high output power.
    • Distribute pure battery backup DC voltage with a minimum of loss. Remove the low reliable DC-AC step in the central backup power system and maximize its reliability and efficiency.
    • Stack cabinets with up to 72 rectifiers to build large power systems monitored by the Smartpack2 controller.
    • The rectifiers Universal Input also allows it being powered from the 380Vdc bus. Static voltage outputs (300-400Vdc) can be realized for 400Vdc remote powering and other applications.

    Technical Specifications - FLATPACK2 380V RECTIFIER
    Model Flatpack2 380/3000HE UI
    Part number 241119.825
    INPUT DATA
    Voltage range (nominal) 176 - 277 VAC / 260 - 400 VDC1)
    Voltage (operating range) 85 - 305 VAC / 260 - 410 VDC1)
    Frequency 45 - 66 Hz / 15 - 18.5 Hz2) / DC1)
    Maximum current 18.2 ARMS
    Power Factor 0.99 (@ 50-100% load)
    Protection Fuse in both lines, varistor for transient protection, shutdown when VIN is out of range
    OUTPUT DATA
    Default voltage 381 VDC
    Voltage range 300 - 400 VDC
    # Pb cell supported 156 - 168 3)
    Max power, nominal input 3000 W (@VOUT ≥ 48VDC)
    Power (maximum) @ 85 VDC / 85 VAC input 1200 W
    Current continuous (maximum) 9 A (@VOUT < 336 VDC) / 7.9 A (@ VOUT = 381 VDC)
    Hold-up time, default voltage and 1000 W load > 20 ms; output voltage > 300 VDC at 1500 W load
    Current sharing (10 - 100% load) ± 5% of maximum current
    Static Voltage regulation (10 - 100% load) ±0.5%
    Static voltage regulation ±0.5% for 10 - 100% load
    Dynamic voltage regulation ±2.0% for 10-90% or 90-10% load variation, regulation time < 10 ms 5)
    Ripple < 1000 mVP-P , 30 MHz bandwidth
    Protection Overvoltage shutdown, Hot plug-in - Inrush current limiting, ORing diode, Fuse5), Short circuit proof, High temperature protection, Overload shutdown4)
    OTHER SPECIFICATIONS
    Efficiency @ 230 VAC / 380VDC input 96.2% / 96.6%
    Isolation 3.0 kVAC – input to output, 1.5 kVAC – input to earth, 1.5 kVDC – output to earth,
    3.0 kVAC – CAN to primary, 3.0 kVAC – CAN to secondary
    Alarms (Red LED) Low mains shutdown, High and low temperature shutdown, Rectifier Failure,Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure
    Warnings (Yellow LED) Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage
    Normal (Green LED) Input and output ok
    Acoustic noise, at nominal input and full load < 40dBA @Tambient< 25°C / <58dBA @ Tambient> 40°C
    MTBF (Telcordia SR-332 Issue I method III (a)) 2 291 210h (@ Tambient = 25 °C)
    Operating temperature (5 - 95% RH non-cond.) Output power de-rates above temp / to -40 to +75°C (-40 to +167°F), humidity 5 - 95% RH non-condensing
    Output power de-rates linear from 3000W @ 50°C (122°F) to 980W @ 75°C(167°F)
    Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
    Dimensions[WxHxD] / Weight 109 x 41.5 x 327 mm (4.25 x 1.69 x 13”) / < 1.95 kg (4.3 lbs)
    DESIGN STANDARDS
    Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC 60950-1:2013, UL
    60950-1:2014, CSA C22.2 No. 60950-1-07
    EMC EN 61000-6-1:2007, -6-2:2005, -6-3:2007 + A1:2010, -6-4:2007 + A1:2010,
    IEC61000-6-5: 2015, EN 300 386:v1.6.1, FCC CFR 47 Part 15:2013
    Environment Tested according to: ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3)
    Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating
    conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised
    2011/65/EU (RoHS) & 2012/19/EU (WEEE)